AMAX panel 4000 / AMAX panel 4000
62
en | Settings
EN
AC Fault Delay Time
The fault report will be delayed for 1 hour or 10 minutes, or transmitted along with the other
reports. The AC power fault event will be displayed on the keypad 1 hour, or 10 minutes later.
Date / Time Fault
In case of date/time settings fault, it is possible to choose to display the fault or transmit fault
prompt tone at the same time, or to not display and stop fault prompt tone. If it is chosen to
not display, the fault prompt tone is set, and the system will prompt nothing if no date and
time are set after power-up.
Battery Check Interval
This option defines the time interval in which the battery test is carried out. Also battery test
is carried out when armed or during system power up.
Phone Line Monitor
If the option is enabled, the system supervises whether the phone line is broken or
disconnected.
Siren Supervision
If the option is enabled, the system supervises whether the siren is shortened or
disconnected.
Quick Arming
Without any PINs, system quick arming can be made by pressing and holding the keypad # for
3 seconds, or the quick perimeter arming can be made by pressing and holding the keypad *
for 3 seconds.
Installer Access Until Next Arming
Before using installer access, a standard user has to enable installer access first. If the option
installer access until next arming is enabled, installer access permission is limited to next
arming.
Force Arm When System Is In Trouble Condition
If the option is enabled, an area can be force armed however there is trouble condition.
Event Record Count per Set/Unset Period
Option event record count per set / unset period defines the maximum number of records for
an event within the set / unset period.
Language Version
The AMAX panel supports different languages. Select one of the versions available.
Keypad 2 Button Alarm
If the option is enabled, an area can be force armed. However there is a trouble condition.
The emergency alarm will be transmitted, if 1 and 3, or * and # are pressed and held
simultaneously. The fire alarm will be transmitted, if 4 and 6 are pressed and held
simultaneously. The silent keypad emergency alarm will be transmitted, if 7 and 9 are pressed
and held simultaneously.
System Tamper Indication In Area
This option defines where the system tamper event is indicated. System tamper indication can
be assigned to either the area where zone 1 is located in or to all Areas.
Zone Tamper Bypass when DEOL Zone is Bypassed
If the option is enabled, system creates a tamper alarm when DEOL zone is tampered, even
when this zone is bypassed. Modify address 0184 in order to change parameter. This function
is only accessible in address programming.
Enclosure Tamper Timing
The AMAX panel supports different reaction times for the onboard tamper used for panel
enclosure. The reaction time is default 400 ms and can be changed to 150 ms.