NEC Electra Elite 48/192 Features And Specifications Manual page 587

Table of Contents

Advertisement

Issue 6
T - 6
Use Memory Block 2-08 (ECR Relay to Tenant Assignment) to
¥
assign External Tone Ring or Night Chime Relay per tenant. Default
is not assigned.
Use Memory Block 2-09 (DID Limit to Tenant Assignment) to limit the
¥
number of incoming DID calls to a Tenant (System Software S5000
or higher is required).
Use Memory Block 4-09 (Telephone to Tenant Assignment) to
¥
specify Tenant assignment per station (default: All telephones are
assigned to Tenant 00). Call Pick-up groups can be assigned by
Tenant group.
Use Memory Block 4-12 (Line Key Selection for Telephone Mode) to
¥
assign a function (default: CO) to each telephone in a tenant
specified as Telephone mode.
Restrictions:
The Barge-In feature cannot be accessed between tenants unless it
¥
is used for outside lines that are shared by the tenants.
General:
Multiple tenants can share outgoing lines.
¥
Outgoing calls and Add-On Conferences may be accessed between
¥
tenants.
Internal calls may be made to different tenants.
¥
Tenant assignment applies to Multiline Terminals and Single Line
¥
Telephones.
To pick up a call in another tenant, a Call Pickup - Other Tenant
¥
Access Code must be used.
Day/Night Mode Switching can be set per tenant; however, Automatic
¥
Day/Night Mode Switching can only be set system-wide.
System Speed Dial display indication on the LCD of a Multiline
¥
Terminal is assigned per tenant.
Electra Elite
Tenant Service