WALK TEST ?

Walk Test
Description
Use this function to test keypads, detection devices, and sounders
(both interior and exterior) to be certain they function properly.
You can review untested points at your keypad to help pin-point
any problems.
You cannot arm your system while in the walk test mode, and no
alarm reports are sent to your security company unless a 24-
hour point is activated (such as fire or panic).
Upon initiation, the walk test tests the burglary bell pattern on the
bell output and ring the keypad burglary bell for 2 seconds. The
AC is disabled for 4 minutes in order to test the system's battery
power. If the battery cannot maintain the system for the 4 minute
period, the keypad becomes unresponsive. If this happens, contact
your security company. At the end of the 4 minute period, AC is
returned to the system and the panel restores. To test individual
detection devices, simply activate sensors and open protected doors
and windows one-at-a-time. As each detection device is faulted,
the Command Center emits a brief tone and the display indicates
for 60 seconds that the point has been tested. This verifies that
each detection device is working properly.
Using Walk Test:
1.
Ensure your keypad shows idle disarmed text.
2.
Press the COMMAND bar. The display shows SYSTEM
COMMAND.
3.
Press the 4 key, followed by the 4 key.
Note:
If you prefer, you might use the Command Menu in place
of steps 2 and 3 to initiate this function. Press the MENU
key to enter the Command Menu, then press NEXT
repeatedly until you reach the WALK TEST ? prompt.
Press ENT.