Language Distribution System
7.2.15

Reset all options to factory default values (4P)

Use menu item 4P to reset all options to the factory defaults. The user defined transmitters
name, the user defined language names and the transmission mode are not reset. (The default
values are indicated by an asterisk (*) in the menu descriptions.)
Menu Item
4P Defaults ...
4P Defaults ...
7.3

Integrus Radiators

7.3.1

Set the output power selection switch

The radiators can be switched to half power. This can be used when full power is not
required, e.g. when a mobile system is used in a small conference venue.
Also switch a radiator to half power when an adequate air flow can not be guaranteed, e.g.
when the radiator is mounted on top of an interpreters booth.
Reducing the power when possible saves energy and increases the lifetime.
When a radiator is in half power mode, half the number of IREDs are switched off, which
results in a visible pattern as shown in the next figure.
Figure 7.3: IRED pattern of radiator in half power mode.
Bosch Security Systems B.V.
Options
Reset to defaults?
* - No
- Yes
Operation manual
Description
Push the button to go to the sub-menu.
Cancel Reset.
Reset all options to the factory default value.
The user defined transmitters name, the user
defined language names and the transmission
mode are not reset.
Configuration | en
59