HP D5970A - NetServer - LCII User Manual page 65

Hp netserver lp 2000r (1.13, 1.26 & 1.40 ghz) user guide
Hide thumbs Also See for D5970A - NetServer - LCII:
Table of Contents

Advertisement

Chapter 6
3. Tilt the heatsink back towards the hook latch and release the hook latch. Then,
lift the heatsink away from the processor and out of the Netserver.
4. Open the ZIF lever to allow removal of the processor. See Figure 6-2.
5. Hold the processor by its edges and lift it out of the socket. Place it on a static-
dissipating work surface or into an anti-static bag.
6. If you are not replacing the processor with a new or replacement processor,
install the terminator into the empty processor socket. See Figure 6-2.
CAUTION
7. If you intend to use the heatsink again for a new or replacement processor,
you must install a new thermal patch on the bottom of the heatsink.
Refer to "Installing the Heatsink" earlier in this chapter.
CAUTION
If you are using a single processor, you must install a
terminator on the empty processor socket in order for the
Netserver to operate reliably.
Heatsinks are not reusable unless the thermal patch is
replaced each time the heatsink is removed, even if the
heatsink is reinstalled on the same processor.
Installing an Additional Processor
59