Sharp AF-X7BCA Operation Manual page 17

Table of Contents

Advertisement

Drain water method 1:
To get the maximum cooling efficiency, the air conditioner is designed to splash
the condensate on the condenser coil.
If the splashing sound annoys you, you can provide an outside drain by using the
following procedure, which may however cause a small loss of performance.
1. There is a drainage outlet at the back of the unit.
2. Remove cover from the drainage outlet, and then connect drainage joint to it
with screw.
3. Connect the drain hose to the outlet.
Note:
Drain hose or tubing can be purchased locally to satisfy your particular needs.
Drain water method 2:
To get the maximum cooling efficiency, the air conditioner is designed to splash
the condensation water on the condenser coil.
To the cooling only unit, If the splashing sound annoys you, you can provide an
outside drain by using the following procedure, which may however cause a small
loss of performance.
1. Slide out the chassis from the cabinet.
2. Remove the rubber plug from the body base plate.
3. Install the drain pan to the corner of the cabinet with 2 screws.
4. Connect the drain hose to the outlet on the drain pan bottom.
5. Slide the chassis into its original place in the cabinet.
Note:
Drain pan and drain hose must be installed before using reverse cycle models.
Drain hose or tubing can be purchased locally to satisfy your particular needs.
Drainage outlet
Washer
Install
Drainage joint
- 13 -
Remove
Cover