Yamaha 02R96 Owner's Manual page 141

Digital mixing console version 2.0
Hide thumbs Also See for 02R96:
Table of Contents

Advertisement

You can set the Bass Management parameters in the following ranges:
Parameters
HPF 1, 2, 3
LPF1
LPF2
ATT 1 & 2
AMP
The HPF 1, 2, 3, and LPF 1 & 2 values indicate a cut-off frequency and a filter response. For example,
"80-12" means a cutoff frequency of 80 Hz and a filter response of –12 dB/octave.
"L" means Linkwitz filter. Other filters are Butterworth.
MONITOR ALIGNMENT ATT & DLY ON/OFF:
These buttons are used to turn on and off the Monitor
Alignment Attenuator and Delay parameters of all Sur-
round speakers. The MONITOR ALIGNMENT diagram
and Surround Channel Attenuator and Delay parameters,
which are displayed when either of these buttons are
selected, allow you to align the surround monitor speak-
ers by attenuating and delaying Surround Channels as
necessary. The Attenuator parameters can be set –∞,
–12 dB to +12 dB in 0.1 dB steps. The Delay parameters
can be set from 0 to 30 msec in 0.02 msec steps.
Patching Slot Inputs to Surround Channels
Individual Slot Inputs can be patched to Surround Monitor Channels as follows.
Use the MONITOR [DISPLAY] button to locate the Surround Monitor Patch
1
page.
Use the cursor buttons to select the parameters, and use the Parameter
2
wheel, INC/DEC buttons, and [ENTER] button to set them.
SLOT/CH: This patching matrix is used to patch Inputs 1–16 from each of the four Slots
to the Surround Monitor Channels. Each Slot Input can be patched to only one Surround
Monitor Channel.
LEVEL: These parameters are used to set the monitor level of each Slot.
Range
THRU, 80-12, 80-12L, 80-24, 80-24L
THRU, 80-24, 80-24L, 120-42
THRU, 80-24, 80-24L, MUTE
0 to –12 dB (1 dB steps)
0 to +12 dB (1 dB steps)
Surround Monitoring
02R96 Version 2—Owner's Manual