(2) 1 PULSE SR (1 Pulse Svnc Reset)
Charge begins to accumulate after the trigger input operation to the DC IN/SYNC terminal or trigger signal
input (LVDS) to the DIGITAL terminal, the vertical sync signal is reset and field images are output.
The
exposure time is set to 0.06 to 16 ms on the menu.
Trigger pulse level
(DC IN/SYNC terminal)
Trigger pulse fetch timing
Trigger pulse width
Trigger pulse interval
: (Low Level): Less than 0.5V , (High Level): 3.4V to 5V
: Rising edge / Falling edge
selectable
: More than 2
u
s
: More than 33.5 ms
TRIGGER
(DC IN/SYNC terminal)
or
TRIGGER D
(DIGITAL terminal)
Internal VD
VD output
Index output
(INDEX)
Video output
LT
h.
Falling edge mode
Rising edge mode
TRIGGER : Approx. 1.9
u
s
^TRIGGER D : Approx. 2.4
/l<s
<
-H Exposure period
Exposure end
\
11 to 12H
~U-LTTT
"LT