Planning the RF300 system
4.2 Field data for transponders, readers and antennas
Note
Possible reader-transponder combinations
The tables of the following section show the possible reader-transponder combinations.
4.2.1

Field data of RF300 transponders

The limit distances (S
transmission window for each reader-transponder combination are listed in the tables below.
In dynamic mode, make sure that rectangular transponders cross the antenna field in the
longitudinal direction.
Table 4- 2
RF320T
RF330T
RF340T
RF350T
RF360T
RF370T
All values are in mm
The values relate to the RF310R reader as of version "D".
Table 4- 3
RF320T
RF330T
RF340T
RF350T
RF360T
RF370T
RF380T
All values are in mm
52
) and operating distances (S
g
Field data RF310R reader
Length of the transmission
window (L)
30
30
40
45
45
70
Field data RF340R reader
Length of the transmission
window (L)
45
40
80
80
90
85
90
) along with the length of the
a
Operating distance (S
)
a
1...23
2...18
2...36
2...47
2...60
2...45
Operating distance (S
)
a
1...20
2...18
2...50
2...60
2...65
5...60
5...80
System Manual, 07/2017, C79000-G8976-C345-07
Limit distance (S
)
g
26
21
41
53
68
60
Limit distance (S
)
g
25
23
58
75
85
80
100
SIMATIC RF300