Motorola R-2550 Programming Reference Manual page 208

Communications system analyzer
Table of Contents

Advertisement

2 Thermal Power Meter Remote Commands
MT (R-2600) (LPA
Description:
Command Syntax:
Standard B-232
Response Syntax:
Response Syntax:
Parameters:
Description:
Notes:
Motorola Communications Analyzer
option only)
The MT command selects and controls the Thermal Power meter.
Description:
Thermal Power Meter Range
Yes
Type:
units:
None
Resolution:
Range:
1:
Low ( -15.0 through 0.0 dBm)
2: High ( -5.0 through +lO.O dBm)
Reset:
0
Thermal Power Measurement
Description:
Type:
units:
0.01 dE%m
Resolution:
nl = 1: -15.0 through 4.0
Range:
nl = 2: -5.0 through +lO.O
Thermal Power Measurement
Type:
units:
Resolution:
nl = 1: 0.0001 mW
nl = 2: 0.001 mW
Range:
nl = 1: 0.0316 through 1.00
nl = 2: 0.316 through 10.000
The M?, ?, or *TRG queries will return the given response following the issuance of the
MT command.