Notes:
1.00
Description:
Current Delta Frequency, or Absolute Marker Frequency Result
Type:
units:
Resolution:
0.1 MHZ
Range:
Delta Measurement:
Absolute Measurement:
Current Delta Power, or Absolute Marker Power Level Result
Description:
Type:
units:
Resolution:
0.1 dBm
Range:
Delta Measurement
Absolute Measurement
The M?, ?, or *TRG queries will return the given response following the issuance of the
OS Command. Each query returns the next peak measurement.
Selection of 2,5, or 10 MHz for the nZ parameter is not available on the R-2550.
Selection for parameters n3, n4, n5 will result in an Error 08 being returned by the
R-2550.
Selection of 2,5, or 10 MHz for the nl parameter is available on the R-2600 only
Enhanced Spectrum Analyzer Option is installed. Zf the option is not installed, the
analyzer will return an Znvalid Input Error (Error 08).
Selection for parameters n3, n4, n.5, and responses for parameters n6 and n7 are valid
on the R-2600 only
if
is not installed, the analyzer will return an Invalid Input Error (Error 08).
135
0 through 100.0 MHz
0 through 1000.0 MHz
-60 through +60
-60 through +50
Motorola Communications Analyzer
Programming Reference
(continued)