Maintenance and repairs
5.2 Cleaning and caring for the device
Procedure
1. If a project is running on the HMI device, close the project.
2. Switch off the HMI device.
3. Coarse cleaning with water.
4. Apply detergents or disinfectants according to the manufacturer's instructions.
5. Allow the detergents or disinfectants to act as specified by the manufacturer.
6. Rinse with drinking water.
Procedure in case of cross-contamination
If there is a possibility of cross-contamination (e.g. hand contact with products) during
operation, follow the procedure below:
• Remove visible buildup immediately.
• Avoid direct contact of foodstuff with the anti-shatter film.
• Prevent foodstuff removed from the device from getting back into the production process.
5.2.3
Working with pressure washers
The HMI device can be used on machines that are cleaned with high pressure.
NOTICE
Damage caused by steam cleaners
Hot steam can damage the HMI device. Do not clean the HMI device with steam cleaners.
Risk of contamination by high-pressure cleaner
When high-pressure cleaners are used, areas that have already been cleaned can be
contaminated again:
• Due to particles of dirt or aerosols swirling up
• Due to draining wastewater
This is why high-pressure cleaners are generally not recommended for machine and plant
cleaning in the hygiene sector.