Conettix Ethernet Communication
Module
1: Legacy Panel Mode is enabled.
This option allows the module to support legacy control panels that communicate using
Datagram Mode 0. When Legacy Panel Mode is enabled, the module uses the Local Port
parameter as both the source port and destination port for communication.
The control panels that use Legacy Panel Mode are:
Port 77EE Configuration Enable
Default: No
Selections: Yes, No
Yes: The network configuration port is enabled. The remote application software can configure
the module through this port.
No: The network configuration port is disabled. The remote application software cannot
configure the module through this port.
Port number 77EE (hexadecimal code) is reserved for configuration of the module by the
remote application software.
UPnP Enable
Default: Yes
Selections: Yes, No
Yes: UPnP is enabled.
No: UPnP is disabled.
Universal Plug and Play (UPnP) allows devices to connect seamlessly and simplifies the
implementation of personal and corporate networks. When enabled in the premises router,
this feature is used to automatically setup port forwarding rules for Remote Programming
traffic to the control panel.
HTTP Port Number
Default: 80
Selections: 1 to 65535
Use this option to configure the port number for the module web server.
ARP Cache Timeout
Default: 600
Selections: 1 to 600 (in 1-sec increments)
When the module communicates with any device on a network, an entry is added to its ARP
table for each of those devices. The ARP Cache Timeout defines the number of seconds (1 to
600) before the ARP table of the module is refreshed.
5.9

Panel Address Settings page

The Panel Address Setting option only works when the address rotary switch on the module
is set to 0 (local configuration setting). If the address switch is set to a position other than 0,
the set address is displayed.
Bosch Security Systems, Inc.
GV2 Series v7.05 and lower
G Series v6.99 and lower
DS7400XiV4
Installation and Operation Guide (UL)
Configuration | en
21
2013.08 | 02 | F.01U.281.208