Advanced Network Settings Page - Bosch B426 Installation And Operation Manual

Conettix ethernet communication module
Table of Contents

Advertisement

20
en | Configuration
Default: 7700
Selection: 0 to 65535
This parameter sets the local port number that the module listens to for in-coming network
traffic.
The TCP/UDP Port is typically configured as 7700 when the control panel is communicating
with the B5512 and B4512, a central station receiver, RPS, Automation or Remote Security
Control. Port numbers are assigned in various ways based on three ranges:
Note: In order to limit unwanted traffic, select a number above 1023.
Legacy TCP Automation Enable
Default: No
Selection: Yes, No
When enabled, creates and maintains two separate TCP connections used to interface with
automation software or Remote Security Control (RSC) application on B Series control panels.
TCP Keep Alive Time
Default: 45
Selection: 0 – 65 (0: Disable, 1 - 65: Keepalive Time in sec)
Select how many seconds the unit waits during a silent connection before attempting to see if
the currently connected network device is still on the network. If there is no response, it
drops the connection.
5.8

Advanced Network Settings page

Figure 5.4: Advanced Network Settings page
Legacy Panel Mode
Default: 0 (Disable)
Selections: 0, 1
0: Legacy Panel Mode is disabled.
2013.08 | 02 | F.01U.281.208
System Ports: 0 to 1023
User Ports: 1024 to 49151
Dynamic or Private Ports: 49152 to 65535
Installation and Operation Guide (UL)
Conettix Ethernet Communication
Module
Bosch Security Systems, Inc.