11. When the ENTER key is pressed, message screen is displayed in
the following order. Operate the zoom ring in accordance with
the message.
Zoom ring
12. When the ENTER key is pressed, automatically starts the zoom
AD check.
13. After the zoom AD check is completed, automatically starts the
mechanical end adjustment.
14. "LENS DEVICE FOCUS MECHANICAL END ADJUSTMENT
OK" is displayed, press the ENTER key.
15. When the ENTER key is pressed, recording the adjustment data
and releasing from adjustment mode are performed automatically,
and "FINISHED" is displayed when the process is completed,
then click the [OK] button.
(3) Steady Hall (S)
• Adjust the position detection hall element for shake compensation.
Subject
Operation on Lens side
Shooting Mode of the camera P mode (Program Auto)
Adjusting Method
1. Click the [Steady Hall (S)] button in the Adjustment and Inspec-
tion, the adjustment will start.
2. "FINISHED" is displayed when the adjustment is completed,
then click the [OK] button.