16. When the ENTER key is pressed, automatically starts the focus-
ing ring AD value check.
17. After the focusing ring AD value check is completed, message
screen is displayed in the following. Set the iris click switch to
the "ON", the IRIS LOCK switch to the "RELEASE" and iris
ring to the "A" (Auto).
IRIS LOCK
Iris ring
switch
Iris click switch
18. When the ENTER key is pressed, message screen is displayed
in the following. Set the iris ring to the "22".
Iris ring
19. When the ENTER key is pressed, automatically starts the iris
ring adjustment.
22
16
20. After the iris ring adjustment is completed, the message screen
is displayed in the following order. According to the instructions
of the screen, check the iris ring in order of "22" to "A", by one
graduation every.
21. After the iris ring check is completed, message screen is displayed
in the following. Set the ZOOM switch to the "SERVO".
ZOOM switch
5-27