Removing the Electric Motor (continued)
Installing the Electric Motor
Electrical System: Service and Repairs
4. Support the electric motor to prevent it from falling.
5. Remove the 4 socket-head screws (item 3 in
electric motor to the motor adaptor (4).
6. Carefully slide the electric motor from the transmission, and remove the
motor from the machine.
7. Remove the key (7) from the motor shaft.
8. Remove and discard the closed cell foam seal (item 6 in
the motor shaft.
1. Install the closed cell foam seal (6) onto the electric motor shaft.
2. Apply a coat of anti-seize to the key (7) and install the key onto the motor
shaft.
3. Position the electric motor to the transmission, align the motor-shaft key of
the to the transmission coupler, and insert the motor shaft into the coupler.
Slide the motor fully to the motor adaptor (4).
4. Secure the electric motor to the motor adaptor (4) with the 4 socket-head
screws (3).
5. Connect the electric motor connections to the machine wire harness.
6. Connect the battery pack; refer to
Battery Pack (page
Disconnecting and Connecting the Lithium
5–3).