Installing The Position Monitoring Kit - Bosch Rexroth HQ 5/H Assembly Instructions Manual

Table of Contents

Advertisement

20/60
Assembly
Required accessories
• Proximity switch A
3 842 555 390
• Proximity switch B + C
3 842 549 811 or
3 842 549 814
• 2 x switch brackets
3 842 537 289
Please note:
The mounting position of
the position monitoring
kit (F) is derived from the
dimensions C1 and C2
(position of the proximity
switch A for querying the
WT) in the dimensions table
on Page 27.
1.
Install the switching fl ag
on the lift frame of the
lift transverse unit.
2.
Assemble the position
monitoring kit including
switch bracket.
3.
Install the position
monitoring kit from
below on the lift frame.
4.
Install the proximity
switches.
Proximity
Query
switches
A
WT
B
Upper end
position
C
Lower end
position
Bosch Rexroth AG, MIT: HQ 5/H, HQ 5/XH, 3 842 558 544/2017-07
7.5.2

Installing the position monitoring kit

b/b
b/b
F
2
2
Fig. 5:
Installing the position monitoring kit (example shown here with SEW motor mounting)
F
1
3
= 650/845
Q
= 455
Q
2
2
2
A
B
C
557 617-37