Figure 15-17 M3 Screw Position - Motorola DIMETRA MTS 2 Installation, Configuration And Basic Service Manual

Hide thumbs Also See for DIMETRA MTS 2:
Table of Contents

Advertisement

MTS 2 and MTS 4 Installation, Configuration and Basic Service Manual
Procedure 15-12 How to Extract the Module Cage from MTS 2 (Continued)
5
6
7
8
Procedure 15-13 How to Assemble the Module Cage in the MTS 4 Cabinet
1
2
3
4
6802800U74-N September 2009
Remove bottom plate by removing the 20 pcs M3 TEXTRON screws using M1.5 Hex.

Figure 15-17 M3 Screw position

Remove the Ribbon cable from the Module cage.
Mount the two brackets to the Module cage using 10 pcs. M4 screws.
Bend in the area at the back of the Module Cages for Ribbon cables to be routed through later.
Remove the Module Cage Beauty Plate (if any).
Mount all cables going from the lower Module Cage in your specific configuration and fix them
temporarily in the rack before mounting the air separator shelf and module cage.
This would typically be:
Assemble the Air Separator shelf above the existing Module Cage using four M6 screws.
Assemble the Module Cage extracted from MTS 2 in
For more information regarding assembling of a module cage in the MTS 4 Cabinet,
see Adding Additional Module Cage to MTS 4.
• Ethernet cables from Base Radio(s) in lower Module Cage to SC
in upper Module Cage (SC2).
• Ethernet cables from Base Radio(s) in upper Module Cage to SC
in lower Module Cage (SC1).
• CAN Bus cables to and from Filters.
Procedure
15-12.
How to Install
15-41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dimetra mts 4