5.13 CALCULATOR INTERFACE ELECTRONICS CHECKOUT
The
Calculator
Interface
Electronics
are
checked
by
running
the
diagnostic
programs
for the
Laser
Transducer
System,
Option
250.
These
programs
are
stored
on
the
Diagnostic
Cassette
(PM
05501-10001)
that
is
shipped
with
each
system.
I t
is
assumed
in
the
following
discussion
that
you
understand
and
can
operate
the
9825A
Calculator.
5.14 Diagnostic Cassette File Structure
The diagnostic programs for the 5501A Laser Transducer Option 250 are contained in a cassette
tape for the 9825A Calculator. There are several programs stored on the cassette which are
used for testing the Calculator lnterface Electronics. The file locations for each program are
listed below:
File Number Program
0
Test Configuration Program (see Figure 5-72)
1
Test Program (see Figure 5-73)
2
Storage File
3
Blank
4
Test Configuration Program Duplication
5
Test Program Duplication
6
User Defined Keys
7
Automatic Compensator Test
NOTE
The cassette is unprotected since both read and write oper-
ations take place on the cassette during the running of the test.
Take care not to record (rcf) anything on this cassette.