Thank you for choosing Panasonic photovoltaic module HIT
Please read this manual completely before you install or use
TM
HIT
. With proper operation and maintenance, HIT
provide you with clean, renewable solar electricity for many
years. This manual contains important installation, mainte-
nance and safety information. The word "module" as used in
this manual refers to one or more PV modules. Retain this
manual for future reference.
TM
VBHNxxxKJ01 series
TM
.
TM
will
CONTENTS
・GENERAL INFORMATION
・SPECIAL CONDITIONS
"HIT" is a trademark of the Panasonic Group.
Other product and service names listed in this
manual are trademarks or registered trademarks
of respective companies.
2
3
5
6
7
8
9

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic HIT VBHN SJ53 Series

  • Page 1: Table Of Contents

    ・DISPOSAL OF OLD EQUIPMENT DISCLAIMER OF LIABILITY CUSTOMER SERVICES Thank you for choosing Panasonic photovoltaic module HIT “HIT” is a trademark of the Panasonic Group. Please read this manual completely before you install or use Other product and service names listed in this .
  • Page 2: Safety Precautions

     vices such as ground fault, fuses, Do not puncture or damage the installed by Panasonic. There are no and disconnects may be required. back sheet of a module. Do not use user serviceable parts within the the PV modules and make a replace- ...
  • Page 3: Module Specifications

    MODULE SPECIFICATIONS 1000W/m , 25°C cell temperature, determining voltage ratings, con- AM1.5 and solar spectral irradiance ductor capacities, fuse sizes, and  Module specifications are shown in according to IEC 60904-3. size of controls connected to the Table 1 and Figure 1. (Electrical module output.
  • Page 4 Dimensions in mm Back side * The positions of the holes are all symmetrical against the center of the module. Side Front side Section A-A’ Section B-B’ Note) A module is installed using 4 points, symmetrical mounting within setting range (shaded). Setting range parameters are shown in “Mount Locations and Load Resistance”...
  • Page 5: Standards

    STANDARDS produce flying brands. heating and array current reduction.  JUNCTION BOX AND TERMINALS All modules are equipped with fac- VBHNxxxSJ53 and VBHNxxxKJ01 series tory installed bypass diodes. The comply with the requirements of IE-  Modules equipped with one junc- factory installed diodes provide C61215, IEC61730-1, IEC61730-2 and the tion box contain terminals for both...
  • Page 6: Installation

    Conditions. An installation location with conditions beyond the Operating Condi- tions or with other Special Conditions (see below) should be avoided. Operat- ing Conditions of Panasonic modules are as follows: Figure 4. Fixing of cables 1) The modules should be operated only and connectors in terrestrial applications.
  • Page 7: Module Installation

    Panasonic recom- mends to install modules at a slope   Clearance of 100mm between the Please contact your Panasonic Au- steeper than the water gradient. roof surface and module frame is thorized Representative with ques-  required to allow cooling air to cir-...
  • Page 8: Wiring

     Use copper wire which is insulated  Please contact your Panasonic Au- to withstand the maximum possible thorized Representative with ques- system open circuit voltage. For tions regarding other electrical con- applications where wire conduits nections if needed.
  • Page 9: Maintenance

    © SANYO Electric Co., Ltd. 2018 the hazards of electric shock or inju- may be deteriorated or damaged. SANYO is part of the Panasonic Group and is in charge of the manufacturing process of HIT DISPOSAL OF OLD EQUIPMENT...