42 / 52
Error causes and troubleshooting
Table 22: Status LED for operating and error display on the front panel
Symbol, LED
Power
13
Error causes and troubleshooting
13.1
Error causes and troubleshooting
For information on the error display on the front panel, refer to
display" on page 41
Table 23: Error causes and troubleshooting
Error
No image visible
Distorted display due to incorrect display resolu-
tion
"NO SIGNAL" on the display
Bosch Rexroth AG
Display
LED green
LED off
LED orange
Meaning
Normal mode
No supply voltage of DC
24 V
•
No screen signal
present
•
Connected control
cabinet PC is booting
⮫ Chapter 12.3 "Operating and error
Correction
•
Connect the supply voltage and check the
X1S1 connection
•
Connect the display port or CDI+ cables cor-
rectly
•
If panels with display port are used, use only
Bosch Rexroth display cables to connect the
panels, refer to .
•
Set the correct display resolution in the
graphic driver. The standard resolution of the
Windows images (also for the recovery sticks)
is FullHD (1920 × 1080). Set the correct value
once when displays with a smaller resolution
are used
•
Restart the control cabinet PC
•
Check the cabling of the graphic interface.
•
Check the selected video interface and correct
the setting in "On Screen" menu if required.
Setting upon delivery: "RX" (for XCDI+rx).
ctrlX HMI DE0015, DE0021
Action
-
Check the supply voltage
•
Check video connec-
tion
•
Wait until the system
completed booting
R911405731, Edition 03