20 / 52
Interface keypad
WARNING
9.8.1
Overview
Table 17: Keypad interfaces
Name at the
Connection type
housing
CN1
Keypad connection
CN2
Keypad connection
9.8.2
Keypad connection scheme
S1
NOT-HALT
Fig. 7: Keypad connection diagram
Bosch Rexroth AG
Death or lethal injury due to incorrect handling of the E-STOP button
−
The E-STOP button can be used as operating element in an E-STOP
circuit.
−
The E-STOP circuit has to be designed by the machine manufacturer.
−
Only qualified staff may connect the E-STOP button and check it after-
wards.
−
It has to be connected acc. to the connection scheme
"Keypad connection scheme " on page
−
The max. load current is 500 mA.
CN2
S2
S3
20.
Connector type (inte-
grated)
Phönix pin contact strip,
6-pin, MCV 1,5/6-G-3,5
Phönix pin contact strip,
10-pin, MCV 1,5/10-
G-3,5
S4
ctrlX HMI DE0015, DE0021
⮫ Chapter 9.8.2
Mating connector or
cable (from outside)
Phönix socket strip,
6-pin, FK-MCP 1,5/6-
ST-3,5
Phönix socket strip,
10-pin, FK-MCP 1,5/10-
ST-3,5
CN1
LED4
LED2
R911405731, Edition 03