Maintenance and repair | Hägglunds DUc Drive unit
Frequent checks
… Unusual vibrations or noises
… Fluid leaks
… Fluid level in the tank
… The unit is clean
… The air flow paths not are blocked
… Pressure levels normal - stable
… Actuator speeds normal - stable
… Operating temperature
… The drive is running smoothly
… Contamination indicators on the filters
… Check and clean the oil pan
Scheduled maintenance
Planned maintenance at specific time intervals, including the following checks and
actions:
… All points under frequent checks
… Check all pressure levels
… Check for stable temperature levels around the system
… Drain water and sludge from the tank at the drain tap
… Check the electric motor
… Check the function of monitoring equipment/switches, etc
… Cleaning.
High pressure washing
Damage on equipment
▶ Never use a high pressure washing system to clean inside the Drive Unit
… Check the cables
… Check drain line flows and drain line oil condition
… Check the hoses, couplings and pump(s), with respect to cracks, leakages and
condition
… Check the shaft coupling through the inspection hole.
NOTICE
RE 15326-WA, Version 06.2020, Bosch Rexroth AB