Bosch Rexroth Hagglunds DUc MS2 Installation & Maintenance Manual page 44

Drive unit
Table of Contents

Advertisement

44/88
Hägglunds DUc Drive unit | Installation
Bosch Rexroth AB, Version 06.2020, RE 15326-WA
Air flow
HDC and
BOL 16-30
Air flow
BOL 725-2000
x 4
Fig. 34: Mounting of air-oil cooler step 1
Lift up the air-oil cooler.
Note! Never lift the air-oil cooler with lift eyes on the electric motor.
Mount the air-oil cooler on the brackets with screws,washers and nuts included in
the delivery. Check that all screws and nuts are properly tightened. (See Fig. 33)
C2
Fig. 35: Mounting of air-oil cooler, step 2
Connect hydraulic hoses included in the delivery.
DD00098788
DD00098789
C1