Rearranging The Harnesses - Sony WLL-RX50 Maintenance Manual

Wireless camera receiver
Hide thumbs Also See for WLL-RX50:
Table of Contents

Advertisement

1-8. Rearranging the Harnesses

When disconnect the harnesses and the coaxial cables in replacing the parts, rearrange them as shown in
the figure.
Connect the coaxial cables on the MDM-11 board referring to the following table.
Coaxial cable (color)
Coaxial cable (red)
Coaxial cable (green)
Coaxial cable (black)
Coaxial cable (brown)
n
An extreme care should be taken in connecting/disconnecting the coaxial cables.
For details, refer to the Section 1-14-4.
AC IN
Switching
Regulator
CN1
POWER switch
WLL-RX50
Connected between
CN401/MDM-11 board and STREAM EXT IN 1 connector
CN431/MDM-11 board and STREAM EXT IN 2 connector
CN480/MDM-11 board and STREAM OUTPUT 1 connector
CN481/MDM-11 board and STREAM OUTPUT 2 connector
STREAM
OUTPUT1
STREAM
OUTPUT2
DC IN 10.5 - 17V
Brown
Wiring stopper
Black
CN1002
CN1001
CN2
CN1003
Wiring stopper
CN401 (Red)
CN431 (Green)
CN480 (Black)
CN481 (Brown)
Wiring stopper
CN1
KY-540 board
STREAM
EXT IN2
STREAM
EXT IN1 IF OUTPUT
Green
Red
CN101
MDM-11 board
CN703 CN702
CN701
CN1
LCD module
KY-539 board
IF INPUT
1-5 (E)