1. All RF System Adjustment
(1) Insert the alignment tape SR5-1/SR5-1P, then search the alignment tape 00:01:00 in time code.
(DNW-A22: SR5-1, DNW-A22P: SR5-1P)
(2) To enter the maintenance mode, press S1101(G-1) on the SS-63 board.
(3) Enter A17 : A11-A16 ALL ADJUST in the maintenance mode.
. Displays "Auto Adjust (Push SET)" on the video monitor.
(4) Press the SET button on the lower control panel.
. Starts the automatically adjustment.
. Displays "Auto Adjust Complete" on the video monitor after the automatically adjustment is
completed.
(5) To exist A17 : A11-A16 ALL ADJUST, press the MENU button on the lower control panel.
(6) Enter A1F : NV-RAM CONTROL.
(7) Execute "SAVE ALL ADJUST DATA".
. Displays "Save Complete" on the video monitor after the data save is completed.
(8) To exist the maintenance mode, press the MENU button four times.
(9) Eject the alignment tape SR5-1/SR5-1P.
2. EQ RF Output Level Adjustment for BETACAM/BETACAM SP PB
Measuring equipment: Oscilloscope (Band width limit: ON)
(1) To enter the maintenance mode, press S1101(G-1) of SS-63 board.
(2) Enter A3 : BETACAM PB ADJUST of the maintenance mode.
(3) Enter A30 : EQ VR.
(4) Set the specified data to all items of A30 : EQ VR.
Item of A30 : EQ VR
RF GAIN METAL-Y-A
RF GAIN METAL-Y-B
RF GAIN METAL-C-A
RF GAIN METAL-C-B
RF GAIN OXIDE-Y-A
RF GAIN OXIDE-Y-B
RF GAIN OXIDE-C-A
RF GAIN OXIDE-C-B
DNW-A22/A22P
Setting data for DNW-A22
55
55
3F
3F
72
72
5A
5A
Setting data for DNW-A22P
8E
8E
6C
6C
9C
9C
81
81
6-4. EQ-56 Board Replacement
6-71