The error can be analyzed more closely based on the error value:
● Error value [1]: The trolley is moving at a velocity of >20% (reference value is P0) forward
or backward.
● Error value [2]: The hoist is moving at a velocity of >3% (reference value is P40) in the
lowering direction.
A movement in the hoisting direction does not result in an error message.
● Error value [3]: Error values [1] and [2] are present simultaneously.
Error type:
Remedy:
E59 (Bit 19) Monitoring bay scanner
If the value COUNT_BAYSCANNER does not change within a period of 500 ms, error message
E59 is output (see Chapter Using a bay scanner (Page 204)).
This message does not interrupt travel. The user must implement the desired response in the
higher-level control system.
Error type:
Remedy:
10.5.3.7

Other errors 2

E60 (Bit 15) Diagonal pull present
Diagonal pull is present.
This error has no effect on the operating behavior. The user is free to choose the error
response. If you want the response to be "braking at maximum acceleration", you can program
this error bit in the higher-level control system to reset the TRAVEL control bit.
Error type:
Remedy:
E61 (Bit 7) Sway control off (pendulum length)
The sway control function has been switched off because the effective pendulum length is not
within the specified limits (P83, P84).
Note
The sway control function is not switched off and the error E61 is not output if the specified limits
are exceeded as a result of the digital or analog correction of the effective pendulum length (see
Chapter Effective pendulum length correction (Page 337)).
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
Error
Start travel in semi-automatic mode with lower starting velocities only
(see error values).
Error
Check the bay scanner
Error
Eliminate the diagonal pull by executing manual travel or change the
setting of parameter P105.
Alarm, error, and system messages