The message "Redundant Ctlr Autocfg
Inactive" will appear.
Power-off Controller 1, and then power-
on Controller 2. Set Controller 2 to
"Autocfg" as described in the above
steps. Power-off Controller 2.
When the redundant controller function is set to the "Automatic"
setting, the controllers will decide among themselves which will be the
Primary or Secondary controller. If you need to specify a particular
controller as Primary or Secondary, do not set it as "autocfg"; choose
"primary" or "secondary" instead. Refer to the following section.

Redundant Configuration Using Manual Setting

Power-on
Controller
Controller 2 is powered-off.
Press ENT for two seconds on the front
panel of Controller 1 to enter the Main
Menu. Use t or s to navigate through
the menus. Choose "View and Edit
Peripheral Dev..", then press ENT.
Choose "Set Peripheral Device Entry",
then press ENT.
Chapter 9 Redundant Controller
Redundant
Autocfg Inactive
1.
Make
sure
View and Edit
Peripheral Dev
Set Peripheral
Devices Entry
Ctlr:
193