Bosch SCD110 Operating Instructions Manual

Bosch SCD110 Operating Instructions Manual

Sense, connect, detect
Hide thumbs Also See for SCD110:

Advertisement

Quick Links

SCD110 Sense | Connect | Detect
Operating Instructions / Version 2.0

Advertisement

Table of Contents
loading

Summary of Contents for Bosch SCD110

  • Page 1 SCD110 Sense | Connect | Detect Operating Instructions / Version 2.0...
  • Page 2: Table Of Contents

    SCD110 Operating Instructions v2.0 2 | 27 Table of Contents 1 About the Operating Instructions 1.1 Definition of Special Notices ....................5 1.2 Definition of General Notices ....................5 2 Safety and Intended Use 2.1 Intended Use ........................6 2.2 Disposal ..........................6 3 Introduction 3.1 Scope of Delivery .........................
  • Page 3 SCD110 Operating Instructions v2.0 3 | 27 5 Installation and Start to Use 5.1 Mounting the SCD ......................10 5.2 Connecting to the SCD ...................... 10 5.3 SCD App Tabs ........................12 5.4 Configuring the SCD ......................13 5.5 Threshold Setting ....................... 14 5.6 Streaming ...........................
  • Page 4 SCD110 Operating Instructions v2.0 4 | 27 10 Regulatory and Legal Information 10.1 Target Markets........................24 10.2 European Union Notices ....................24 10.3 USA: FCC Notices ......................25 10.4 Canada: ISED Notices ....................... 25 10.5 IMDA Singapore Notices ....................25 10.6 ACMA Australia Notices .....................
  • Page 5: About The Operating Instructions

    Bluetooth interface. This document refers to SCD110 firmware version 1.3.0. Please ensure that your SCD110 device is working correctly by reading these instructions before using it in your applications. Please visit the device webpage for more information: https://www.bosch-...
  • Page 6: Intended Use

    SCD110 Operating Instructions v2.0 6 | 27 2.1 Intended Use The SCD110 is designed for monitoring purposes and is not certified as a device to ensure functional safety. The SCD is intended for the following application areas: Environments Residential, commercial, light-industrial, and industrial Please consider following operating conditions for the SCD110 device.
  • Page 7: Technical Specification

    SCD110 Operating Instructions v2.0 7 | 27 On button Green/Red LED Screw holes Note Please don’t cover the SCD with additional labels or stickers. Otherwise, the function of the light sensor cannot be guaranteed. 4 Technical Specification 4.1 Housing The SCD is built from a robust housing suited for industrial use with a self-adhesive back.
  • Page 8: Device Specifications

    ± 0.25 °C Light 0 … 188000 Lux ± 15% Note Specified accuracies refer to the inbuilt sensors. The accuracy and responsiveness of the SCD110 might deviate from sensor specifications, depending on installation conditions and environmental influences. 4.7 Resolution ENSOR...
  • Page 9: Communication

    SCD110 Operating Instructions v2.0 9 | 27 4.8 Communication ATTRIBUTE VALUE Communication Bluetooth Low Energy BLE 4.2 Range up to 40 m (dependent on external influences) 4.9 User Interface ATTRIBUTE VALUE SCD Sensor App Free smartphone app for configuration, read-out and visualization.
  • Page 10: Installation And Start To Use

    5.2 Connecting to the SCD  Download the SCD Sensor App. The App is available for free in the Apple App Store or Google Play Store. Please search for “Bosch SCD” or use the QR-Codes below. Apple App Store Google Play Store ...
  • Page 11 SCD110 Operating Instructions v2.0 11 | 27 After you start the app, the help screens offer you a short overview of the most important functions. Please have a look.  After starting, the app shows a search button. Click on the search button to find devices.
  • Page 12: Scd App Tabs

    SCD110 Operating Instructions v2.0 12 | 27  Choose your SCD by tapping on your device in the list of devices to establish the connection between the SCD device and the smartphone / tablet. 5.3 SCD App Tabs The App has different pages shown in the screenshot below.
  • Page 13: Configuring The Scd

    SCD110 Operating Instructions v2.0 13 | 27 5.4 Configuring the SCD  Tap on the Settings icon.  To ensure easy identification of your devices, please rename your SCD by tapping on the pencil and typing in your preferred name. Then tap Rename.
  • Page 14: Threshold Setting

    SCD110 Operating Instructions v2.0 14 | 27 5.5 Threshold Setting The thresholds are used for threshold monitoring in SCD. When the thresholds are violated, SCD sends an alarm via BLE. In this case the app shows the measurement values in red color. Event before the App connects the SCD, the threshold violations can be seen in connect/scan page with a red device icon.
  • Page 15: Data On The Chart

    SCD110 Operating Instructions v2.0 15 | 27 5.7 Data on the Chart  Tap on the Diagram icon.  Select the sensors you want to see in the chart by tapping the sensor icons. The graphics and values are then displayed.
  • Page 16: Chart View Options

    SCD110 Operating Instructions v2.0 16 | 27 5.7.1 Chart View Options a. Refresh: If the user zooms in on the chart, tap on this icon to restore the original view. b. Enable/disable scrolling in the visible window to show all X values in the graph.
  • Page 17: Logging And Transferring The Data

    SCD110 Operating Instructions v2.0 17 | 27 5.8 Logging and Transferring the Data function stores raw data in the SCD internal memory. Data can be transmitted to the smartphone via SCD app or to the gateway over the BLE. ...
  • Page 18 SCD110 Operating Instructions v2.0 18 | 27  Confirm the logging start  The data is stored locally in SCD until the memory is full or until the logging is stopped by the user.  The data is ready to download.
  • Page 19: Removing The Scd

    SCD110 Operating Instructions v2.0 19 | 27 Note The downloading process may take several minutes. Logging must be stopped in order to proceed with the download. Note Please note that SCD can log only one axis (z-axis) in 6.4 kHz sampling rate. Logging 3-axis in this speed is not possible.
  • Page 20: General Operating Modes Of Scd

    SCD110 Operating Instructions v2.0 20 | 27 6 General Operating Modes of SCD The operation modes are described in this chapter. For information about how to configure the SCD or how to retrieve data from it, please refer to chapter 5 Installation and Start to Use.
  • Page 21: Log File Format

    SCD110 Operating Instructions v2.0 21 | 27 6.4.1 Log File Format The log file is formatted as comma separated values (*.csv). The filename includes the name of the SCD and a timestamp when the data was downloaded. The log file looks like in the following screenshot. There is a header part includes different information about the device, sensors and settings.
  • Page 22: Event Detection Mode

    SCD110 Operating Instructions v2.0 22 | 27 Note The user can select in the app which sensor should be included in the log file. If the user selects more than one sensor and filter the sensor values afterwards in Excel, this can be done easily by using Excel filters.
  • Page 23 SCD110 Operating Instructions v2.0 23 | 27 8 Further Product Related Information Please find all product related documents and user guides on our website: https://www.bosch-connectivity.com/products/industry-4-0/sense-connect-detect/downloads/ Download the SCD Sensor App Apple App Store Google Play Store 9 Trouble Shooting Problem...
  • Page 24: Regulatory And Legal Information

     Frequency band: 2400 – 2483.5 MHz RoHS The SCD110 meets the requirements of the Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS Directive). REACH The SCD110 meets the requirements of the Directive 1907/2006 (REACH Directive, as of: July 2019) and does not contain substances of very high concern as specified in the REACH Directive in concentrations which require notification.
  • Page 25: Usa: Fcc Notices

    SCD110 according to FCC rule parts 15 C with the FCC ID: 2ADSJSCD110 The certification for the United States of America only applies to SCD110 devices with the FCC ID printed on the housing. The user shall verify before using the SCD110 in the United States of America.
  • Page 26: Japan Notice

    The same applies for any kind of weapon, or any device or application which is potentially dangerous for human life. The SCD110 is designed for monitoring purposes and shall not be used as an element of control and safety in machines under the scope of the Machinery Directive 2006/42/EC.
  • Page 27: Open Source License Condition

    27 | 27 10.13 Open Source License Condition The SCD110 embedded software contains open source software (OSS) components. The OSS copyrights and license conditions are provided in the SCD Quick Start Guide that accompanies the device in the sales packaging.

This manual is also suitable for:

262-scd

Table of Contents