Bosch SCD 110 Operating Instructions Manual

Bosch SCD 110 Operating Instructions Manual

Hide thumbs Also See for SCD 110:

Advertisement

Quick Links

SCD 110 Sense | Connect | Detect
Operating Instructions

Advertisement

Table of Contents
loading

Summary of Contents for Bosch SCD 110

  • Page 1 SCD 110 Sense | Connect | Detect Operating Instructions...
  • Page 2: Table Of Contents

    About these operating instructions | Compliant use 2 | 24 Table of contents 1 About these operating instructions 1.1 Compliant use ........................5 1.2 Definition of special notices ....................5 1.3 Definition of general notices ....................5 2 Safety and environment 2.1 Radio frequency radiation exposure and further information ..........
  • Page 3 About these operating instructions | Compliant use 3 | 24 4.10 Communication interfaces ....................8 5 First steps 5.1 Mounting the SCD ........................ 9 5.2 Connecting to the SCD ......................9 5.3 Configuring the SCD ......................11 5.4 General information ......................12 5.5 Thresholds ..........................
  • Page 4 About these operating instructions | Compliant use 4 | 24 10 Regulatory and legal information about the SCD 10.1 European Union notices ..................... 21 10.2 USA: FCC notices ......................21 10.3 IMDA Singapore notices ..................... 21 10.4 ACMA Australia notices ...................... 22 10.5 China notice ........................
  • Page 5: About These Operating Instructions

    This document presents the SCD operating instructions, detailed SCD sensor characteristics as well as communication and management features through Bluetooth. This document refers to SCD firmware version 1.3.0. https://www.bosch- Detailed instructions on how to proceed are available at: connectivity.com/products/sense-connect-detect Ensure that the SCD is working correctly by reading these instructions carefully before using the SCD in your planned application.
  • Page 6: Radio Frequency Radiation Exposure And Further Information

    Introduction | Radio frequency radiation exposure and further information 6 | 24 2.1 Radio frequency radiation exposure and further information The radiated output power of the device is far below the FCC radio frequency exposure limits. Nevertheless, the device must be used in such a manner that the potential for human contact during 4.3).
  • Page 7: Technical Specification

    Technical specification | Housing 7 | 24 4 Technical specification 4.1 Housing The SCD is built from a robust housing suited for industrial use with a self-adhesive back. The compact design of the SCD fits perfectly in different industrial applications and enables easy, user-friendly mounting in difficult-to-access environments.
  • Page 8: Measurement Range And Accuracies

    Technical specification | Measurement range and accuracies 8 | 24 4.5 Measurement range and accuracies ENSOR EASUREMENT ANGE CCURACY Acceleration ± 200 g ± 10% Magnetometer ± 1300 µT (X, Y-Axis); ± 2500 µT (Z- ± 5% Axis) Temperature -20 °C … + 85 °C ±...
  • Page 9: First Steps

    First steps | Mounting the SCD 9 | 24 5 First steps 5.1 Mounting the SCD The SCD housing has a self-adhesive back for mounting. The surface must be flat • • clean • in order to mount the SCD. Mounting the SCD: ...
  • Page 10 First steps | Connecting to the SCD 10 | 24 After you start the app, the help screens offer you a short overview of the most important functions.  When starting the app, the search button is shown. Click on the search button to find devices. TIP: In order to select the right SCD when multiple are available, move your smartphone/tablet close to the desired SCD.
  • Page 11: Configuring The Scd

    First steps | Configuring the SCD 11 | 24  Choose your SCD by tapping on your device in the list of devices to establish the connection between the SCD device and the smartphone / tablet. 5.3 Configuring the SCD ...
  • Page 12: General Information

    First steps | General information 12 | 24 After renaming the device, you must wait 5–10 seconds. Afterward, you must establish the connection again. 5.4 General information a. See help screens related to the area you are currently in. b. Disconnect: Click on the Disconnect icon if you want to disconnect your device. c.
  • Page 13: Thresholds

    First steps | Thresholds 13 | 24 5.5 Thresholds The threshold function monitors the streamed or logged values and triggers corresponding alarms via BLE if values are out of a defined range.  Set the threshold values by tapping the Settings icon. If the values deviate from the defined range, they are displayed in the app in red.
  • Page 14 First steps | Streaming 14 | 24  Tap on the Diagram icon.  Select the sensors you want to see in the chart by tapping the sensor icons. The graphs and values are then displayed. TIP: Values outside of the defined range are shown in red. Data subject not change without notice | Printed in Germany | October 19 | Version 1.0 BCDS/GM...
  • Page 15: Logging And Transferring Data

    First steps | Logging and transferring data 15 | 24 Options using the chart view a. Refresh: If the user zooms in on the chart, tap on this icon to restore the original view. b. Enable/disable scrolling in the visible window to show all X values in the graph. c.
  • Page 16 First steps | Logging and transferring data 16 | 24  Set the desired values.  Tap on "Start logging".  Confirm the settings. Data subject not change without notice | Printed in Germany | October 19 | Version 1.0 BCDS/GM...
  • Page 17 First steps | Logging and transferring data 17 | 24  The data is stored until the memory is full or logging is stopped.  The data is ready for download. Note The downloading process may take several minutes. Logging must be stopped in order to proceed with the data transfer.
  • Page 18: Removing The Scd

    General operation modes | Removing the SCD 18 | 24 5.8 Removing the SCD  Run a flat tool without a sharp edge between the SCD and the surface.  Carefully lift the SCD and release it from the machine. INFO: Do not use any sharp objects to remove the SCD.
  • Page 19: Logging Data To The Local Memory

    General operation modes | Logging data to the local memory 19 | 24 6.3 Logging data to the local memory When the SCD is configured to log measurements to its local memory, a file will be created in the user data memory.
  • Page 20: Maintenance

    Liquid which enters the device can cause short circuits and damage the device. This could cause fire, data loss and incorrect measurements. 8 Further product related information Please find all product related documents and user guides on our website: https://www.bosch-connectivity.com/products/industry-4-0/sense-connect-detect/downloads/ Download the SCD Sensor App Apple App Store Google Play Store...
  • Page 21: Regulatory And Legal Information About The Scd

    European Union notices Radio Equipment Directive Bosch Connected Devices and Solutions GmbH hereby declares that the radio equipment type "SCD" is in compliance with Directive 2014/53/EU (Radio Equipment Directive). The full text of the EU declaration of conformity is available at the following internet address: https://www.bosch-connectivity.com/products/industry-4-0/sense-connect-...
  • Page 22: Acma Australia Notices

    Bosch product could create a situation where personal injury or death may occur.
  • Page 23: Open Source License Condition

    The OSS copyrights and license conditions are provided in the file "DataStreamer_v02.01.01_FOSS_Disclaimer.txt" which can be read after connection of the SCD via USB as a mass storage device to your PC. For further assistance, please refer to http://www.bosch-connectivity.com/SCD or e-mail support@bosch- connectivity.com...
  • Page 24 Regulatory and legal information about the SCD | Open source license condition 24 | 24 Bosch Connected Devices and Solutions GmbH Ludwig-Erhard-Straße 2 72760 Reutlingen Deutschland www.bosch-connectivity.com Data subject not change without notice | Printed in Germany | October 19 | Version 1.0...

Table of Contents