3) Release the harness for the stapler drive unit from the 3 wire saddles, and then remove 2 connectors (10P and 2P).
1) Remove the stapler unit.
(Refer to page 4-40)
2) Remove the Grate-shaped
lower guide.
(Refer to page 4-26)
4) Remove the 2 screws and open the finisher controller
PCB mount.
x2
4
Parts Replacement and Cleaning Procedure > Main Units > Removing the Stapler Drive Unit
x2
5) Disconnect the sensor connector and release the motor harness from the 2 wire saddles and the edge saddle.
Disconnect the motor connector and release the motor harness from the wire saddle.
F-4-55
F-4-55
x2
4-28
F-4-54
F-4-54
F-4-56
F-4-56
4-28