HP 37718A Installation And Verification Manual page 116

Hide thumbs Also See for 37718A:
Table of Contents

Advertisement

Performance Tests
SDH/SONET Receiver Equalization
.
2 Set the
TRANSMIT
3 Connect Cable Simulator STS-1 between the 52/155 Mb/s 75Ω DATA
OUT and 52/155 Mb/s 75Ω DATA IN ports.
4 Press
RESULTS
measurement.
5 Ensure that NO TROUBLE is displayed on the
30 seconds.
6 Press
RUN/STOP
3-76
display as shown below.
then
TROUBLE SCAN
to stop the measurement.
to start the
RUN/STOP
display after
RESULTS