Diagnostics
10.3 Safety messages for SINAMICS S120
Remedy
N30620 (F, A)
Response
Acknowledgment
Explanation
Remedy
Response for F
Acknowledgment for F IMMEDIATELY (POWER ON)
Response for A:
Acknowledgment for A NONE
10-784
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
Re fault value = 1 to 5 and 7 to 999:
-- Check the crosswise compared data that resulted in a STOP F.
-- Carry out a POWER ON (power off/on) for all components.
-- Upgrade the Motor Module software.
-- Upgrade the Control Unit software.
For fault value = 6:
-- Carry out a POWER ON (power off/on) for all components.
-- Upgrade the Motor Module software.
-- Upgrade the Control Unit software.
For fault value = 1000:
-- Check the wiring of the safety--related inputs (SGE) on the Control
Unit (contact problems).
For fault value = 1001, 1002:
-- Carry out a POWER ON (power off/on) for all components.
-- Upgrade the Motor Module software.
-- Upgrade the Control Unit software.
Re fault value = 2000, 2001, 2002, 2003:
-- Check the tolerance time SGE changeover and if required, increase
the value (p9650, p9850, p9652/p9852).
-- Check the wiring of the safety--related inputs (SGE) (contact
problems).
-- Check the reason why STO was selected in r9872. For active SMM
functions (p9501 = 1), STO can also be selected as a result of these
functions.
-- Replace the Motor Module involved.
This fault can be acknowledged after resolving the cause of fault and
after selecting/deselecting STO.
SI P2: Safe torque off active
NONE
NONE
The "Safe Torque Off" (STO) function of the basis functions has been
selected on monitoring channel 2 via the input terminal and is active.
Note:
This message does not result in a safety stop response.
Not necessary.
OFF2
NONE
© Siemens AG 2015 All Rights Reserved