Diagnostics
10.3 Safety messages for SINAMICS S120
C01798
Response
Acknowledgment
Explanation
Remedy
C01799
Response
Acknowledgment
Explanation
Remedy
List of faults and alarms (Motor Module)
F30600
Response
Acknowledgment
Explanation
10-782
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
SI Motion P1 (CU): Test stop running
NONE
IMMEDIATELY (POWER ON)
The test stop is active.
Not necessary.
The message is withdrawn when the test stop is completed.
SI Motion P1 (CU): Acceptance test mode active
NONE
IMMEDIATELY (POWER ON)
The acceptance test mode is active.
The following applies to safety functions with SINUMERIK:
The power on messages of the safe motion monitoring functions can
be acknowledged during the acceptance test using the acknowledg-
ment options of the higher--level control.
Not necessary.
The message is withdrawn when exiting the acceptance test mode.
SI P2: STOP A initiated
OFF2
IMMEDIATELY (POWER ON)
The "Safety Integrated" function integrated in the drive on monitoring
channel to has detected a fault and initiated a STOP A (STO via the
safety shutdown path of monitoring channel 2).
-- Forced checking procedure of the safety shutdown path of the
monitoring channel unsuccessful.
-- Subsequent response to fault F30611 (defect in a monitoring
channel).
Fault value (r0949, interpret decimal):
0:
Stop request from the Control Unit
1005: STO active, although STO not selected and there is no internal STOP
A present.
1010: STO inactive although STO is selected or an internal STOP A is
present.
1011: Internal error for STO deselected in monitoring channel 2.
1020: Internal software error in the "Internal voltage protection" function.
The "Internal voltage protection" function is cancelled. A STOP A that
cannot be acknowledged is initiated.
9999: Subsequent response to fault F30611
© Siemens AG 2015 All Rights Reserved