7. MAINTENANCE OPERATION
(2) Specifying a memory dump file
1. Click Start > Control Panel > System and Security. Then click System.
2. Under Task on the left side of the window, click Advanced system settings.
3. If you see the User Account Control window, click Yes.
4. In the Advanced tab page, click Settings under Setup and Recovery.
5. In the Dump file box, type a memory dump file name.
By default, "%SystemRoot%\MEMORY.DMP" is specified for this box.
Unless it is necessary, you do not have to enter a name.
6. Select the Overwrite any existing file check box.
7. Click OK.
In order to enable a Complete memory dump as recommended for this equipment, follow
the procedure below.
1. In the search box that is displayed by clicking the Start button in the lower left corner,
enter the following and press Enter.
C:\Program Files\HFWRAS\init\SetCrashDump.reg
(Alternately, double-click the SetCrashDump.reg file under C:\Program
Files\HFWRAS\init.)
2. If you see the User Account Control window, click Yes.
3. The following message box will open. Click Yes.
4. A message box will appear indicating that information has been added successfully.
Click OK.
(3) Enabling automatic restart after a memory dump
1. Click Start > Control Panel > System and Security. Then click System.
2. Under Task on the left side of the window, click Advanced system settings.
3. If you see the User Account Control window, click Yes.
4. On the Advanced tab page, click Settings under Setup and Recovery.
5. If you want to restart the equipment after a memory dump, select the Automatically
restart check box. If you want to stop the equipment after a memory dump, clear the
Automatically restart check box.
6. Click OK.
7-12