Bosch PSI 6XXX.350 L1 Series Technical Information page 81

Timer and i/o level
Table of Contents

Advertisement

Electrical connection
<Without weld process monitoring>
7-40
This signal indicates that welding is performed without current monitoring.
If current monitoring is switched off, deviations from the tolerance band in current moni-
toring are not detected. This may lead to weld quality impairment.
NOTE
When weld process monitoring has been deactivated, you should always check the qual-
ity of your welds.
Monitoring stopped
Current
monitoring
off
off
on
on
Figure 23: Monitoring
NOTE
Monitoring stopped is activated and deactivated for all timers (for all programs of the
selected timer) in the Basic Setup, in the menu Sequence Setup.
Current monitoring is activated and deactivated for specific programs with the Welding
Parameters option in the Current Monitoring window.
PSI 6XXX.350 L1
for all timers
on
on: without monitoring
off
on
off
off: with monitoring
Weld process monitoring function
on: without monitoring
on: without monitoring
1070 080 067-101 (2001.03) GB