Advertisement

Issue 10/06
6.4.3

Digital input (DIN)

Function digital input 1
P0701 = ...
Terminal 5
1
ON / OFF1
Function digital input 2
P0702 = ...
Terminal 6
12
Reverse
P0703 = ...
Function digital input 3
Terminal 7
9
Fault acknowledge
Function digital input 4
P0704 = ...
Terminal 8
15
Fixed setpoint (Direct selection)
Function digital input 5
P0705 = ...
Terminal 16
15
Fixed setpoint (Direct selection)
Function digital input 6
P0706 = ...
Terminal 17
15
Fixed setpoint (Direct selection)
Function digital input 7
P0707 = 0
Via analog input, Terminal 3
0
Digital input disabled
Function digital input 8
P0708 = 0
Via analog input, Terminal 10
0
Digital input disabled
P0724 = ...
Debounce time for digital inputs
Defines debounce time (filtering time) used for digital inputs.
0
No debounce time
1
2.5 ms debounce time
2
8.2 ms debounce time
3
12.3 ms debounce time
PNP / NPN digital inputs
P0725 = ...
Change-over (toggles) between high active (PNP) and low active (NPN). This applies to all
digital inputs simultaneously.
0
NPN mode ==> low active
1
PNP mode ==> high active
DIN channel (e.g. DIN1 - PNP (P0725 = 1))
Kl.9
P24 (PNP)
Kl.28
0 V (NPN)
MICROMASTER 440
Operating Instructions (Compact)
1
Possible Settings:
0
1
2
12
3
4
9
10
9
11
12
13
14
15
15
16
17
21
15
25
29
33
99
15
0
0
PNP/NPN DIN
0 ... 1
P0725 (1)
Debounce time: DIN
24 V
0
0
24 V
1
1
0 V
Digital input disabled
ON / OFF1
ON + Reverse / OFF1
OFF2 – coast to standstill
OFF3 – quick ramp-down
Fault acknowledge
JOG right
JOG left
Reverse
MOP up (increase frequency)
MOP down (decrease frequency)
Fixed setpoint (Direct selection)
Fixed setpoint (Direct selection + ON)
Fixed setpoint (Binary coded selection + ON)
Local/remote
DC brake enable
External trip
Disable additional freq setpoint
Enable BICO parameterization
ON > 3,9 V, OFF < 1,7 V
DIN7
1
2
3
4
0 ... 3
P0724 (3)
T
0
&
r0722
r0722
CO/BO: Bin.inp.val
6 Commissioning
DIN8
1
2
10
11
3
1
P0701
Function
Pxxxx BI: ...