Connecting the C Controller module with CW Workbench
Connect the user Ethernet port CH1 of the C Controller module with CW Workbench to perform debugging in CW Workbench.
Operating procedure
1.
To acquire a VxWorks image file from the C Controller module, start Explorer and enter the following address in the
address bar.
ftp://192.168.3.3/SYSTEMROM/OS_IMAGEFILE/
The "Log On As" screen appears.
To communicate between the C Controller module and the personal computer, specify the same VxWorks
image file for both.
2.
Enter the following user name and password in the "Log On As" screen.
• User name: target
• Password: password
3.
Click the [Log On] button.
4.
Create "C:\MELSEC\R12CCPU-V\CCPUTool" folder, and copy the VxWorks image file stored in the C Controller module
to the folder.
8 OPERATION EXAMPLE
8.3 Programming
8