Problem
The RCP operates,
but the touch
screen is dark
The RCP operates,
but one or more of
the RCP controls
do not work
62
Probable Cause
1. The touch screen
power button was not
pressed during startup.
2. The touch screen
brightness is turned
down.
3. One or both touch
screen cables are
disconnected or
broken.
4. A component in the
RCP or touch screen
has failed.
1. A component in the
RCP has failed.
Corrective Action
1. Press the touch screen
power button.
2. Readjust the touch screen
brightness.
3. Connect or replace the touch
screen cables.
4. Contact your Telemetrics
representative for
assistance.
1. Contact your Telemetrics
representative for
assistance.