GE C70 Instruction Manual page 564

Capacitor bank protection and control system ur series
Hide thumbs Also See for C70:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 36 of 65)
ADDR
REGISTER NAME
User Programmable Pushbuttons (Read/Write Setting) (16 modules)
7B60
User Programmable Pushbutton 1 Function
7B61
User Programmable Pushbutton 1 Top Line
7B6B
User Programmable Pushbutton 1 On Text
7B75
User Programmable Pushbutton 1 Off Text
B
7B7F
User Programmable Pushbutton 1 Drop-Out Time
7B80
User Programmable Pushbutton 1 Target
7B81
User Programmable Pushbutton 1 Events
7B82
User Programmable Pushbutton 1 LED Operand
7B84
User Programmable Pushbutton 1 Autoreset Delay
7B85
User Programmable Pushbutton 1 Autoreset Function
7B86
User Programmable Pushbutton 1 Local Lock Operand
7B88
User Programmable Pushbutton 1 Message Priority
7B89
User Programmable Pushbutton 1 Remote Lock Operand
7B8B
User Programmable Pushbutton 1 Reset Operand
7B8D
User Programmable Pushbutton 1 Set Operand
7B8F
User Programmable Pushbutton 1 Hold
7B90
...Repeated for User Programmable Pushbutton 2
7BC0
...Repeated for User Programmable Pushbutton 3
7BF0
...Repeated for User Programmable Pushbutton 4
7C20
...Repeated for User Programmable Pushbutton 5
7C50
...Repeated for User Programmable Pushbutton 6
7C80
...Repeated for User Programmable Pushbutton 7
7CB0
...Repeated for User Programmable Pushbutton 8
7DE0
...Repeated for User Programmable Pushbutton 9
7D10
...Repeated for User Programmable Pushbutton 10
7D40
...Repeated for User Programmable Pushbutton 11
7D70
...Repeated for User Programmable Pushbutton 12
7DA0
...Repeated for User Programmable Pushbutton 13
7DD0
...Repeated for User Programmable Pushbutton 14
7E00
...Repeated for User Programmable Pushbutton 15
7E30
...Repeated for User Programmable Pushbutton 16
Neutral Overvoltage (Read/Write Grouped Setting) (3 modules)
7F00
Neutral Overvoltage 1 Function
7F01
Neutral Overvoltage 1 Signal Source
7F02
Neutral Overvoltage 1 Pickup
7F03
Neutral Overvoltage 1 Pickup Delay
7F04
Neutral Overvoltage 1 Reset Delay
7F05
Neutral Overvoltage 1 Block
7F07
Neutral Overvoltage 1 Target
7F08
Neutral Overvoltage 1 Events
7F09
Neutral Overvoltage 1 Curves
7F0A
Reserved (7 items)
7F11
...Repeated for Neutral Overvoltage 2
7F22
...Repeated for Neutral Overvoltage 3
Auxiliary Overvoltage (Read/Write Grouped Setting) (3 modules)
7FA0
Auxiliary Overvoltage 1 Function
7FA1
Auxiliary Overvoltage 1 Signal Source
7FA2
Auxiliary Overvoltage 1 Pickup
7FA3
Auxiliary Overvoltage 1 Pickup Delay
7FA4
Auxiliary Overvoltage 1 Reset Delay
7FA5
Auxiliary Overvoltage 1 Block
7FA7
Auxiliary Overvoltage 1 Target
7FA8
Auxiliary Overvoltage 1 Events
B-44
0 to 4294967295
0.2 to 600
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 65535
0 to 4294967295
C70 Capacitor Bank Protection and Control System
RANGE
UNITS
STEP
0 to 2
---
1
---
---
---
---
---
---
---
---
---
0 to 60
s
0.05
0 to 2
---
1
0 to 1
---
1
---
1
s
0.1
0 to 1
---
1
---
1
0 to 2
---
1
---
1
---
1
---
1
0 to 10
s
0.1
0 to 1
---
1
0 to 5
---
1
0 to 3
pu
0.001
0 to 600
s
0.01
0 to 600
s
0.01
---
1
0 to 2
---
1
0 to 1
---
1
0 to 3
---
1
---
1
0 to 1
---
1
0 to 5
---
1
0 to 3
pu
0.001
0 to 600
s
0.01
0 to 600
s
0.01
---
1
0 to 2
---
1
0 to 1
---
1
APPENDIX B
FORMAT
DEFAULT
F137
0 (Disabled)
F202
(none)
F202
(none)
F202
(none)
F001
0
F109
0 (Self-reset)
F102
0 (Disabled)
F300
0
F001
10
F102
0 (Disabled)
F300
0
F220
0 (Disabled)
F300
0
F300
0
F300
0
F001
1
F102
0 (Disabled)
F167
0 (SRC 1)
F001
300
F001
100
F001
100
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F116
0 (Definite Time)
F001
0
F102
0 (Disabled)
F167
0 (SRC 1)
F001
300
F001
100
F001
100
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents