GE C70 Instruction Manual page 539

Capacitor bank protection and control system ur series
Hide thumbs Also See for C70:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 11 of 65)
ADDR
REGISTER NAME
26DF
IEC 61850 GGIO5 uinteger Input 16 Operand
IEC 61850 Received Integers (Read Only Actual Values) (16 modules)
26F0
IEC 61850 Received uinteger 1
26F2
IEC 61850 Received uinteger 2
26F4
IEC 61850 Received uinteger 3
26F6
IEC 61850 Received uinteger 4
26F8
IEC 61850 Received uinteger 5
26FA
IEC 61850 Received uinteger 6
26FC
IEC 61850 Received uinteger 7
26FE
IEC 61850 Received uinteger 8
2700
IEC 61850 Received uinteger 9
2702
IEC 61850 Received uinteger 10
2704
IEC 61850 Received uinteger 11
2706
IEC 61850 Received uinteger 12
2708
IEC 61850 Received uinteger 13
270A
IEC 61850 Received uinteger 14
270C
IEC 61850 Received uinteger 15
270E
IEC 61850 Received uinteger 16
Source Current THD and Harmonics (Read Only) (6 modules)
2800
Ia THD for Source 1
2801
Ia Harmonics for Source 1 - 2nd to 25th (24 items)
2821
Ib THD for Source 1
2822
Ib Harmonics for Source 1 - 2nd to 25th (24 items)
283A
Reserved (8 items)
2842
Ic THD for Source 1
2843
Ic Harmonics for Source 1 - 2nd to 25th (24 items)
285B
Reserved (8 items)
2863
...Repeated for Source 2
28C6
...Repeated for Source 3
2929
...Repeated for Source 4
298C
...Repeated for Source 5
29EF
...Repeated for Source 6
Expanded FlexStates (Read Only)
2B00
FlexStates, one per register (256 items)
Expanded Contact Input/Output States (Read Only)
2D00
Contact Input States, one per register (96 items)
2D80
Contact Output States, one per register (64 items)
2E00
Virtual Output States, one per register (96 items)
Expanded Remote Input/Output Status (Read Only)
2F00
Remote Device States, one per register (32 items)
2F80
Remote Input States, one per register (64 items)
Oscillography Values (Read Only)
3000
Oscillography Number of Triggers
3001
Oscillography Available Records
3002
Oscillography Last Cleared Date
3004
Oscillography Number Of Cycles Per Record
Oscillography Commands (Read/Write Command)
3005
Oscillography Force Trigger
3011
Oscillography Clear Data
Oscillography Analog Values (Read Only)
3012
Oscillography Number of Triggers
User-Programmable Fault Report Commands (Read/Write Command)
3060
User Fault Report Clear
GE Multilin
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 400000000
C70 Capacitor Bank Protection and Control System
RANGE
UNITS
STEP
---
---
---
---
1
---
1
---
1
---
1
---
1
---
1
---
1
---
1
---
1
---
1
---
1
---
1
---
1
---
1
---
1
---
1
0 to 99.9
---
0.1
0 to 99.9
---
0.1
0 to 99.9
---
0.1
0 to 99.9
---
0.1
0 to 0.1
---
0.1
0 to 99.9
---
0.1
0 to 99.9
---
0.1
0 to 0.1
---
0.1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 65535
---
1
0 to 65535
---
1
---
1
0 to 65535
---
1
0 to 1
---
1
0 to 1
---
1
0 to 32767
---
1
0 to 1
---
1
B.4 MEMORY MAPPING
FORMAT
DEFAULT
F612
0
F003
0
F003
0
F003
0
F003
0
F003
0
F003
0
F003
0
F003
0
F003
0
F003
0
F003
0
F003
0
F003
0
F003
0
F003
0
F003
0
F001
0
F001
0
F001
0
F001
0
F001
0
F001
0
F001
0
F001
0
F108
0 (Off)
F108
0 (Off)
F108
0 (Off)
F108
0 (Off)
F155
0 (Offline)
F108
0 (Off)
F001
0
F001
0
F050
0
F001
0
F126
0 (No)
F126
0 (No)
F001
0
F126
0 (No)
B-19
B

Advertisement

Table of Contents
loading

Table of Contents