Sony PCM-7040 Operation Manual page 71

Digital audio recorder
Hide thumbs Also See for PCM-7040:
Table of Contents

Advertisement

7-3 Dial Menu Operations
The display that
appears and the
Data
meaning of the
display
Auto inP (AUTO
INPUT)
oFF*
PuncH io (PUNCH IN/
OUT)
diSAbLE*
EnAbLE
AtF SEnS (ATF SERVO
SENSITIVITY)
nor*
PLAy
[SEt dSP] (SETUP
DISPLAY MENU)
cLoSE*
oPEn
FL diSP (DIMMER)
d-1*
d-2
d-3
d-4
P-HoLd (PEAK HOLD
MODE)
Auto*
HoLd
7-12
Chapter 7 Menu Operations
Functions
Changes the monitoring
mode according to the tape
running mode.
: does not switch
automatically
on
: REPRO (when the PLAY/
REC/CUE mode)
INPUT (the other modes)
Selects the punch in/out
mode with the REC key.
: does not punch in/out when
you press the REC key
: punch in/out when you
press the REC key in the
audio insert mode
Selects the sensitivity when
the servo lock changes to
unlock.
: normal
: Low sensitivity
Effective when the audio
signal is normal, but the
servo is frequently unlocked
with the tape which has low
linearity is played back.
Selects to open the setup
menu of the display.
: close
: open
Adjusts the brightness of the
display on the front panel.
1)
: a maximum bright level
1)
: a 2nd bright level
: a 3rd bright level
: a minimum bright level
1)
The brightness is
automatically dimmed out
when no tape is inside the
unit or the unit is set to
standby off mode (auto
dimmer function).
Selects the peak hold mode
of the level meters.
: holds the peak level as long
as the time you set in
"Hold-t" in the setup menu.
: keeps on holding the peak
level until you press EJECT
key or until you press the
RESET key while holding
down the DATA key.
The display that
appears and the
Data
meaning of the
display
o-HoLd (OVER HOLD
MODE)
on*
oFF
HoLd-t (PEAK HOLD
TIME)
1_5*
4_0
rLS-t (RELEASE TIME)
50*
100
o-SEnS (OVER LEVEL
SENSITIVITY)
2
3
4*
7
[SEt SP] (SETUP
MENU)
cLoSE*
oPEn
Pb cond (PB
CONDITION TALLY)
bAd
cond*
corr
intP
Functions
Selects the hold mode of the
"OVER" segments of the
level meters.
: The segments are kept lit
according to the peak hold
mode setting by "P-HoLd".
: The segments are not kept
lit.
Selects the peak level hold
time of the level meters.
: 1.5 sec
: 4 sec
Selects the release time for
the level meters.
: 50 msec
: 100 msec
Selects the level detection
sensitivity that lights the
"OVER" segments of the
level meters.
: 1 Word
: 2 Word
: 3 Word
: 4 Word
:
:
: 7 Word
Selects to open the signal
processing menu of the
setup menu.
: close
: open
Selects the condition that
causes the PB CONDITION
indicator on the front panel to
light.
: lights if the error rate
increases and interpolation
or muting might occurs
: lights when an error occurs
and a correction is made
: lights when an error occurs
and interpolation is done