The Operator Circuit (OCT) has a different signalling group with respect to the other
PMC circuits. This means that it has to be defined with PE code 4020. The PCT type is 01
and the signalling group 280E.
If connected to a DLC-C/D:
Also in this configuration PE code 4020 is used. The PCT type is 01 and the signalling group
of this Operator Circuit (OCT) is 280E.
If connected to a DLC-U or a DTX-I (not in SSW 200/205):
The Operator Circuit may only be projected in SSW 300. Use PE code 4020. The PCT
type is 01 and the signalling group is 0911.
3. Define whether passwords must be used. If so, define whether one or more passwords
are required. To define the password structure use PE command 4160 with the following
options for the 'OP-TYPE':
2 = Password per user;
3 = One password per console
4 = No password.
With OM MML command ASPSWD or OM command 3139 a password may be assigned
to the User Identification Number (USIN) or to the DNR of the operator circuit. This way
a password can also be redefined which is useful if a user has forgotten the password.
4. For signalling groups 280E (in SSW 200/205 and SSW 300) and 0911 (only in SSW 300) a
number of parameters may be changed. It concerns:
-
Transmit/receive levels;
-
Default language;
-
Activation/deactivation of downloading the level/language;
-
Supervisor type.
The first two parameters can be defined by means of PE command 4400. The last two
parameters may be defined with PE command 4401.
If you want to change the default parameters consult the appropriate section in this
chapter. If not, set the operator circuit in service.
PROCEDURE: Projecting in SSW 735 Onwards
The SV25/35 may be connected to DTX-I or a DLC-C/D/U board. Execute the following
steps:
Actions
1. Check which row in
package."
is applicable to your system and execute the action mentioned in the "action"
column.
2. Project the DOC, DTX-I or DLC in the normal way as an extension with OM command
ASBRDS.