Service; Pressure Test; Carrier Panel Removal; Figure 030-2: Carrier Panel Retaining Screws - Miele CVA 2650 Technical Information

Hide thumbs Also See for CVA 2650:
Table of Contents

Advertisement

CVA 265x & CVA 266x
4

Service

4.1

Pressure Test

See Section 060-4.6.
4.2

Carrier Panel Removal

1. Remove the appliance for service; see Section 010-4.1.
2. Remove the left and right side panels.
3. Remove the rear panel.
4. Remove the top casing (Section 010-4.5).
5. Open the door.
6. Remove the panel retaining screws (Figure 030-2, Item 1).

Figure 030-2: Carrier Panel Retaining Screws

7. Note the wiring positions and disconnect from the master on/off switch.
8. Remove the two T10 screws securing the door wiring harness retainer.
9. Disconnect the Teflon hose at the brew unit connection (Figure 030-3, Item 3)
and pull the hose free.
10. Disconnect the Teflon hose at the ceramic valve connection (Figure 030-3,
Item 1) and pull the hose free.
11.
Disconnect the Teflon hose at the steam valve connection (Figure 030-3,
Item 2) and pull the hose free.
39