9. Disconnect or unscrew all necessary connections and ground leads.
10. Move the front casing forward. Lift to remove.
Figure 010-9: Front Casing Retaining Screws
4.7
Valve Housing Seal Removal
1. Disconnect the appliance from the power supply.
2. Open the door.
3. Remove the water tank.
4. Lever off the cap holder with an appropriate tool and remove the cap; see
Figure 010-10, Item 1.
5. Remove the seal; see Figure 010-10, Item 2.