Term
Factory defaults
Fail to Communicate
Fast Format Channels
Faults
Feature Select
FF Channel
File n
File to Panel
Files
Final Set Door
Fire
Fire light
Fire Siren
Fire Supervision
Fire Verification Time
Fire Window
Fire/Aux 1 (1+3)
First to Open/Last to
Close
Definition
The default control panel values that are set in the factory. Each country has a
country code and associated default values. To use these values, default the
panel and then select the country code. The default values are filled into the
control panel the moment the country code is selected.
A menu option that sends a report to the central station when the system has
failed to communicate with the central station after the number of attempts set in
FTC Dialler Attempts. The report is sent when communication with the central
station has been restored. (System Reports)
A menu option that reports a fail to communicate event to the selected phone
number. (Phone Numbers)
A menu entry that groups the report codes sent to the central station when a fail to
communicate event occurs. (Report Codes)
A menu option that reports a fail to communicate event to the central station
depending on the condition of the panel dialler. (CS7001 GSM Module)
See also Panel Dialler OK Events and Panel Dialler Not OK Events
A menu option that specifies which Fast Format channels are enabled. These are
grouped as Channels 1 – 8 and Channels 9 – 16.
Any problems with the system. Zones that are open are referred to as faulted.
A menu entry that groups all optional features relating to partition settings, control
panel system settings and so on.
A menu option that specifies that the Fast Format channel format is used to report
the selected zone, zone type or event.
A menu option that selects the programming memories within the CS586 direct
connect module. There are four possible programming memories.
A menu option to copy programming memory from one of the four memory
locations contained in the CS586 direct connect module, to the control panel.
A menu entry that groups the four programming memories in the CS586 direct
connect module.
A zone type that arms the system the moment the exit door is closed. It differs
from an exit terminator zone in that it is available in the standard CSx75 and is
attached to a zone that can also create alarms and so on.
A zone type that reports a fire alarm when activated.
An LED light indicating the status of a fire zone. A steady fire light means a fire
zone has been faulted. A rapidly flashing fire light means that a fire zone is in a
trouble condition.
A menu option that sets the type of siren activated when a fire alarm occurs. This
can be either yelping or temporal.
A menu option that specifies that the RF433 or RF868 receiver uses the fire
supervision timing window.
A menu option that sets the amount of time within which a second trip must occur
on a smoke detector in order to generate an alarm.
A menu option that specifies the RF supervision to be used for RF smoke/fire
detectors. The RF smoke/fire detectors send a supervision every 64 minutes,
irrespective of 433 Mhz or 868 Mhz.
See also Supervision
A menu option that activates keys 1 and 3 as the fire alarm combination keys.
When this option is enabled and these keys are pressed at the same time, a fire
alarm is generated.
A menu option that sends a report to the central station stating when the system
opened and closed. This option can only be used in a multi-partitioned system.
A report is sent stating the first area opened. A log is then kept recording when the
other areas opened and when they closed. This information is sent in a second
report when the last open area closes.