e) The cutting volume of the scanner leading image edge.
(1) Place the scale (its end to the left side original scale) on the original glass and make an A4-
100% copy.
(2) In order to delete the copy of scale mark just for 2 mm from the leading edge of the paper,
adjust as follows.
0
5
3
PWR
Notes 1. An increase in the value makes the image move to the leading edge of the paper
(0.1213 mm/step).
2. In order to make a test copy, make sure the message indicates [ 100 %
after the INT key is pressed.
3. Adjustment value is able to be input within the range of "128 ~ 255".
The default adjustment value is 128.
September 1997 © TOSHIBA CORP.
Copy movement direction
Copied scale
5
10
1
3
START
Set the value
1 - 35
INT
E/S
(Test copy)
2460 ADJUSTMENT
A ]