Toshiba 2460 Service Handbook page 15

Digital plain paper copier
Table of Contents

Advertisement

Code
Adjustment
315 Original leading edge void adjustment
340 Reserved
350 ADF single-sided original stop position
351 ADF two-sided original stop position
356 ADF EEPROM initialization, ADF sensor
automatic adjustment
400 Polygonal motor rotation, fine adjustment, 600dpi Standard PPC 128
401 Polygonal motor rotation, fine adjustment, 600dpi
405 Polygonal motor rotation, fine adjustment, 600dpi Extended PPC 128
410 Laser starting position, 600dpi
412 Laser starting position, 400dpi
421 Secondary scanning reproduction ratio, main
motor speed, fine adjustment
430 Top margin
431 Left margin
432 Right margin
433 Bottom margin
435 Reserved
436 Reserved
437 Reserved
2460 ADJUSTMENT
Initial
Mode
Allowance
value
ALL
0
0~255
ALL
8
0~15
ALL
8
0~15
ALL
114~142 If the value is increased by "1",
GDI
128
114~142 tion ratio is enlarged by approx.
114~142 If the value is increased by "1",
PPC
80
0~255
GDI
96
0~255
PPC
140
1~255
Standard PPC
0
0~255
Standard PPC
0
0~255
Standard PPC
0
–94~255 If the value is increased by "1",
Standard PPC
0
–94~255 If the value is increased by "1",
1 - 12
Contents
0.04233mm/count
the primary scanning reproduc-
0.225%.
the primary scanning reproduc-
tion ratio is increased by approx.
0.225%.
If the value is increased by "1",
the effective image data writing
area on the drum is shifted by
0.0423 mm to the primary scan-
ning direction.
If the value is increased by "1",
the effective image data writing
area on the drum is shifted by
0.0635 mm to the primary scan-
ning direction.
If the value is increased by "1",
the reproduction ratio of the
paper feeding direction is en-
larged by approx. 0.0315%.
If the value is increased by "1",
the white area of the leading
edge is increased by approx.
0.04233 mm.
If the value is increased by "1",
the white area of the left edge
is increased by approx.
0.04233 mm.
the white area of the right edge
is increased by approx.
0.04233 mm.
the white area of the trailing
edge is increased by approx.
0.04233 mm.
September 1997 © TOSHIBA CORP.
Operation
procedure
group
1
1
1
4
1
5
1
5
5
5
1
1
1
1

Hide quick links: