Samsung MOSCON-E7 User Manual page 84

Small general-purpose multi-functional inverter
Table of Contents

Advertisement

Stall Prevention
Setting
Name
Unit
Range
Stall Prevention
P2.01
-
0~1
at Start
Stall Prevention
P2.02
1%
0~200
Level at Start
Stall Prevention
P2.03
1%
0~100
at Acc Limit
Stall Prevention
P2.04
-
0~1
at Stop
Stall Prevention
P2.05
-
0~2
in Running
Stall Prevention
P2.06
1%
0~200
Level in Running
Over Torque Detection
Setting
Name
Unit
Range
Overtorque
P3.01
-
0~4
Detection
Overtorque
P3.02
1%
0~300
Detection Level
Overtorque
P3.03
1sec
0.0~10.0
Delay Time
Retry Fault
Setting
Name
Unit
Range
Number of
P4.01
-
0~10
Fault Retry
Output Terminal
P4.02
-
0~1
Function at Retry
Fan Error
Setting
Name
Unit
Range
P5.01
Fan Error
-
0~1
Appendix
A-11
Factory
Changeable
Page
Setting
During Operation
X
1
5-65
170
¡ Û
5-65
50
¡ Û
5-66
X
1
5-67
X
1
5-68
170
¡ Û
5-68
Factory
Changeable
Page
Setting
During Operation
X
0
5-70
180
¡ Û
5-71
X
0.1
5-71
Factory
Changeable
Page
Setting
During Operation
X
0
5-72
X
0
5-73
Factory
Changeable
Page
Setting
During Operation
X
0
5-73
MOSCON-E7 User's Manual
A-12
Appendix C
E7 Dynamic Brake User's Manual
1. Mounting
For the optimal performance of the dynamic brake, mount it in a place,
which satisfies the conditions listed below.
- Refer to the figure 1 for the dimensions and installation space.
- A dynamic brake and braking resistor generate heat, thus install the
peripheral devices, which are not tolerant to heat, far away from
them.
- Refer to the figure 1 for the mounting method.
Dynamic Brake
96 86
25
64
MOSCON-E7
Figure 1. Mounting method
35.5
)
M4 SCREW (2 places

Advertisement

Table of Contents
loading

Table of Contents